  • Laser emission when framing/moving between patterns

    1. Open RDWorks. 2. Access the user parameter interface. Check that “Go scale mode” is set to “Close laser” (as shown).       If the parameter is correct, check whether the laser signal on the disp...

  • Laser emission despite no coolant flow

    1. Open RDWorks. 2. Access the “Vendor param”(password: rd8888) and check that “Water Protect” is ticked (as shown).                   If the box has been ticked, unplug the line to the WP port on ...

  • Laser emission despite the open cover

    When the machine is in normal standby mode, the tri-color light should be yellow. After opening the cover, the tri-color light should turn red. If the tri-color light turns red but the machine doe...

  • Ammeter always reading about 8mA across the power settings

    Measure the voltage between the IN and GND of the laser power supply 6-pin terminal with the power set at different levels.                                   If the voltage measures similar, the m...

  • Low ammeter readings across the power settings

      Measure the voltage between the IN and GND of the 6-pin terminal with the power set at different levels. If the voltage measures similar, the mainboard is faulty. Replace it with a new, identic...

  • Problems with laser beam

    The laser tube has a finite service life.  Some problems may happen sooner and some even are not problems, though they appear to be. Use the list below to troubleshoot your laser tube that might be...

  • Purplish laser beam

      1. Set the maximum and minimum power to 45% and test. 2. If the color is still purplish, check the current value of the laser power supply. If the current value is too low (less than 5mA). Unplu...

  • Whitish laser beam in the laser tube

      This happens when the gas charge (carbon dioxide) inside the tube is depleting. If in such case, replace the laser tube with a new, identical one.   

  • Reddish laser beam in the laser tube

      This happens when the laser tube is cracked and has been exposed to air. If in such case, replace the laser tube with a new, identical one.   

  • Split beam inside the laser tube

      The laser tube needs to be replaced.